Cabling
Cable testing and certification with written results
This is an add-on service, and plenty of jobs don't need it. Every install we do is labelled and continuity tested as standard. Certification goes further: it measures whether a run meets its category across every pair, and produces a document that says so.
At a glance
- Add-on service: quoted separately
- Cat5e / Cat6 / Cat6a certification
- Fiber insertion loss & OTDR
- Fault location on existing runs
When you need this, and when you don't
If you're running a normal office at Gigabit on newly installed Cat6, you probably don't need certification. The labelling and continuity testing included with every install we do already proves each run is wired correctly end to end, and that's enough.
Certification earns its cost in four situations: a manufacturer warranty depends on it, a landlord or consultant is requiring it in writing, you're taking over cabling somebody else installed and don't trust it, or you're pushing an existing cable plant to 2.5G or 10G and need to know what it will carry. If none of those apply to your job, we'll tell you so rather than sell it to you.
"It works" and "it passes" are different things
A run can carry traffic today and still be out of spec: excess crosstalk, a split pair, a marginal return loss. It will pass a cheap continuity tester and fail under load or at higher speeds. That's the run that causes the intermittent fault nobody can reproduce.
Certification testing measures the parameters that define the category, at every frequency in the band, on every pair. The output is pass or fail against the standard, with the margins shown.
Testing cabling you didn't install
We're regularly asked to certify cabling installed by somebody else, before a lease is signed, after a contractor has left, or when a network has an intermittent problem nobody can pin down. We'll test it, tell you what passes, and give you a list of what needs re-terminating.
What you get
Included as standard unless it says otherwise. Add-ons are priced separately and named as such.
- Copper certificationFull category test on every pair with margins reported.
- Fiber testingInsertion loss on every strand, OTDR traces where useful.
- Fault locationDistance-to-fault so a repair is targeted, not exploratory.
- Re-terminationFailures corrected and re-tested as part of the job.
- Label scheduleRuns identified and labelled if they aren't already.
- Written reportResults supplied in a format you can hand to a landlord or auditor.
The process, start to finish
Every job follows the same shape, so you always know where you are in it.
Scope
We confirm how many runs there are, what category, and whether they're labelled now.
Identify & label
Where the existing labelling is missing or wrong, we tone and trace each run.
Test
Each run is certified to its category, and fiber strands are tested for loss.
Report failures
You get a clear list of what passed, what failed and why.
Remediate
We re-terminate and re-test failures. Usually the fix is at the termination.
Deliver results
You receive the final report and label schedule.
Want this scoped for your site?
Call, or text a photo of the space. You get a straight answer on what the job involves.
Before you call
Isn't testing included when you install cabling?
Labelling both ends and continuity/wire-map testing every run is included on every install. That's part of the job, not an extra. Certification is a different test with different equipment, and it's quoted separately because most jobs don't need it.
Why would I pay to test cabling that already works?
Because 'works' and 'meets spec' aren't the same. Marginal runs are the source of most intermittent network faults, and they only show up under load. That said, if your network is healthy and nothing is requiring the paperwork, this is money you don't need to spend.
Do you test cabling other companies installed?
Yes, frequently. It's common before signing a lease, after taking over a site, or when chasing a fault nobody can reproduce.
What do I receive?
A pass/fail result per run with the measured margins, a list of any failures and their cause, and a label schedule tying it all back to the physical ports.
What if a lot of runs fail?
Most failures are at the termination and are fixed by re-terminating, which we include. If a run is physically damaged in the wall, we'll tell you and quote to re-pull just that one.