Cabling
Cable management and rack clean-ups that stay clean
A messy rack is a downtime risk as well as an eyesore. Nobody can trace a run, nobody wants to touch anything, and a five-minute change becomes an outage. We rebuild racks so the next person can work in them safely.
At a glance
- Full re-dress and re-terminate
- Every port labelled to schedule
- Airflow corrected, power separated from data
- Photographed and documented at hand-over
What a bad rack costs you
In an unmanaged rack nobody can tell which cable goes where, so nobody removes anything, and it gets worse every year. Eventually the only safe change is no change, and a simple move takes an outage window and a nervous technician.
There's a thermal cost too. A wall of slack cable in front of switch exhausts traps heat exactly where you don't want it, and heat is what shortens the life of the most expensive hardware in the room.
What we do
We photograph and map what's live before touching anything, agree a window with you, then re-dress the rack: patch leads to length, horizontal and vertical management, power separated from data, everything labelled to a schedule you keep. Nothing gets unplugged that we haven't recorded first.
What you get
Included as standard unless it says otherwise. Add-ons are priced separately and named as such.
- Pre-work mappingEvery live connection photographed and recorded before we start.
- Correct-length patch leadsNo more three-metre leads bridging a 300 mm gap.
- Horizontal & vertical managementRuns routed through proper management, not cable-tied to the frame.
- Power & data separationMains kept away from data runs to cut induced noise.
- Airflow correctionBlanking panels and clear exhaust paths so kit runs cooler.
- Labelling & documentationPort schedule and photographs handed over.
- Workmanship warrantyIncluded: 1 year from install. Anything our installation caused is fixed at no charge. Equipment carries the manufacturer’s warranty.
The process, start to finish
Every job follows the same shape, so you always know where you are in it.
Assessment
We photograph the rack, map live connections and agree what must stay up.
Plan & window
We agree a change plan and an out-of-hours window with you in writing.
Re-dress
We replace patch leads to length, route runs through the management and separate power from data.
Re-label
Every panel, port and device is labelled to a schedule.
Verify
Each connection is tested and confirmed live again.
Document
You get the photographs, port schedule and rack elevation.
Want this scoped for your site?
Call, or text a photo of the space. You get a straight answer on what the job involves.
Before you call
Will this take our network down?
We plan for no unplanned downtime. Work is done in an agreed window, usually evening or weekend, and every connection is mapped before it's touched and verified after.
Can you do this without replacing our equipment?
Yes. This is a cabling and organisation job. If we do spot hardware that's failing or badly out of date we'll tell you, but we don't need to replace anything to clean up a rack.
How long does a rack clean-up take?
A single 42U rack in reasonable condition is typically one evening. A rack that's been added to for a decade, or a room with several racks, can run to a weekend.
What if our cabling isn't labelled at all?
That's the usual starting point. We tone and trace each run to identify it, then build the label schedule from scratch, which is most of the value of the job.